JC1000 Digital Storage Oscilloscope |
Click for large photo Click for large photo
- Over-thin design,cabinet volume
- Easy to read with color or monochrome (NST) LCD display.
- Dual channel, Bandwith 25~200MHz.
- Sample Rate (Real-time) 500MHz up to 1GSa/s , Equivalent Sampling 50GSa/s.
- 4K channel memory depth.
- Advanced Triggering function from edge,video,pulse,delay.
- +,-,*,÷ Mathematic Functions.
- FFT spectrum analysis:Hanning,Hamming,Blacking,Rectangle.
- Automatic Parameter Measurements:Vpp,Vamp,Vrms,Vmax,Vmin,Vtop,Vbase,Vavg,Freq,
- Period, Risetime,Falltime,+Width,-Width,Overshoot,Preshoot,+Duty,-Duty,etc.
- 10 Waveforms parameter Setups,Save,Reall.
- Vertical scale:2mV∼5V/div
- Sweep time:1ns∼50 s/div
- Rise time:1.8ns∼14ns.
- Power supply:100∼240V, 45∼65Hz,<30W.
- Standard Configuration:USB Device
- Option Configuration:USB Host, Support U-Rardware Storage, Timedisplay
- Dimensions:120(D)285(W)158(H)
Specifications |
JC1202CA |
JC1152CA JC1152MA |
|
JC1062CA JC1062MA |
JC1042MA |
Bandwidth |
200MHz |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
Real time Sample Rate |
1GS/S |
Equivalent Sample Rate |
50GS/S |
Input Impedance |
1MΩ//13pF 50Ω |
Rise time |
1.8ns |
2.3 ns |
3.5 ns |
5.8 ns |
8.8 ns |
Time base Range |
1ns/div-50s/div |
2ns/div-50s/div |
5ns/div-50s/div |
X-Y Operation |
Bandwidth |
200MHz |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
PhaseDHerence |
±3degrees |
Display |
Color LCD(C)/Mono LCD(M)320x240 |
Specifications |
JC1152C JC1152M |
JC1102C JC1102M |
JC1062C JC1062M |
JC1042M |
JC1022M |
Bandwidth |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
25 MHz |
Real time Sample Rate |
500MS/S |
Equivalent Sample Rate |
50GS/S |
Input Impedance |
1MΩ//13pF 50Ω |
Rise time |
2.3 ns |
3.5 ns |
5.8 ns |
8.8 ns |
14ns |
Time base Range |
2ns/div-50s/div |
5ns/div-50s/div |
20ns/div-50ns |
X-Y Operation |
Bandwidth |
150 MHz |
100 MHz |
60 MHz |
40 MHz |
25 MHz |
PhaseDHerence |
±3degrees |
Display |
Color LCD(C)/Mono LCD(M)320x240 |
Common Specifications |
Number of Channel |
2CH;Ext.Trig |
Memory |
4K per channel |
Vertical Sensitivity |
2mv/div-5v/div |
Vertical Resolution |
8bits |
Input Coupling |
DC.AC.GND |
Trigger Mode |
Auto.Normal.Single |
Trigger Type |
Edge.TV.Pulse |
Trigger Coupling |
DC.AC.LF Rej.HF Rej |
Horizontal Accuracy |
±0.01% |
Math |
+,-,*,÷ ,FFT |
FFT |
Window |
Hanning.Hamming.Blackman.Rectangular |
Sample |
1024Points |
Auto Measurement |
Vpp.Vmax.Vmin.Vtop.Vbase.Vamp.Vrms.Vavg.Vover.Vpre Freq.Period.Rise.Fall.+Width.-Width.+Duty.-Duty.DelayA.DelayB |
Cursor Measure |
Manual. Trace. Auto Measure |
Storage |
10Wave forms.10 setups |
I/O |
USB device |
Power |
100V-240V/50VA Max |
Net Weight |
4kg |
Size |
120(D)x285(W)x158(H) |
Accessories |
Probe x 2(1x.10x)Power Cord. User manual | |
|